3-Methyl-2-benzothiazolinone hydrazone hydrochloride monohydrate CAS NO: 38894-11-0
Product description
3-Methyl-2-benzothiazolinone hydrazone hydrochloride monohydrate CAS NO: 38894-11-0
Quick Detail:
Name | MBTH | Appearance | Off- white to light yellow powder |
Assay: | 99.57 | Loss on drying,% | 4.90 |
Color reaction | Blue green | Shelf life | one year |
Description:
> Formula: C8H12ClN3OS
> Weight: 233.718
> Appearance: Off-white to light yellow powder
> MP:270-274℃(Dec.)
> Storage: 2-8℃,keep in dark place
> Danger Description: R25 R36/37/38 R40
> Safety Description:S45 S26 S28A
> Danger Symbol:T
Applications:
1. Applications
A. MBTH is a commonly used spectrophotometric determination of fatty aldehyde reagents.
B. MBTH is also used for determination of the hexose amine mucopolysaccharide.
C. MBTH is also used in spectrophotometric determination of trace selenium in environmental samples.
2. Location
A. Biology/biochemistry laboratory, pharmaceutical factory.
Specifications
Assay | 99.57 |
Loss on drying,% | 4.90 |
Color reaction | Blue green |
Shelf life | One year |
Synonyms:
TIMTEC-BB SBB000722;SAWICKI\'S REAGENT;SAWICKI\'S REAGENT MONOHYDRATE;MBTH;MBTH HCL HYDRATE;MBTH HYDROCHLORIDE HYDRATE;MBTH HYDROCHLORIDE MONOHYDRATE;MBTH MONOHYDRATE;MBTH hydrochloride; 3-Methyl-2-benzothiazolinone hydrazone hydrochloride hydrate; (2Z)-2-hydrazono-3-methyl-2,3-dihydro-1,3-benzothiazole hydrochloride hydrate; (2Z)-2-hydrazinylidene-3-methyl-2,3-dihydro-1,3-benzothiazole hydrochloride (1:1)
Related categories:Xanthones
Related Products:
The determination of Loss on drying
Weigh a sample of approximately 2g (weighing accuracy 0.0001g),Record the weight of m,The sample was placed in a Petri dish constant weight (weight recorded as m0), the tile, the thickness of not more than 5mm, into the oven (As next dish cover removed) drying at 105-110 ℃ 3 hours.When removing, make sure the dish cover,be placed in a desiccator to cool, then weighed and the weight (including surface dish) m1.
Loss on drying in accordance with the following formula:
Where:
m-- sample, g
m0-- dish, g
m1-- After drying the quality of the sample and the dish, g
Determination of melting point
Instrument:
Micro melting point apparatus WRS-2A, Melting point tubes
Determination of step:
Open switch, stable 20min.
First set the starting temperature than the melting point of the low 10 ℃, heating rate 2 ℃ / min.
The sample was grind as fine as possible and load in a clean, dry melting point pipe ,until the sample was compressed into about 1cm high .When the actual temperature reaches the set temperature and stabilized . Inserted into the capillary with the sample, the simultaneous determination of three.