Rechargeable Animal Portable Syringe Pump With Adjustable KVO Rate

Product description


Product Description




Delivery Time:5-7 working days after received payment
Certification:CE/ISO

Rechargeable Animal Portable Syringe Pump With Adjustable KVO Rate​


Product advantages


Multi- language ,Spanish,  English, Russian etc.
All standard 5, 10, 20, 30, and 50(60) syringes applicable. 
Injection modes:Time Mode,  Rate Mode and Body Weight Mode.
Bolus function.
Drug library and factory default function.
Button Operation history records.
Display time and calendar.
4.3 inches colorful LCD screen.

Technical parameters

























































Injection accuracy



±2% 



Bolus rate



50ml:400-1500ml/h           30ml: 400-600ml/h   20ml: 400ml/h        10ml: 200ml/h                    5ml: 100ml/h             



Applicable syringes



All brands of standard syringes: 5, 10, 20, 30 and 50 (60) ml



Injection rate range



5ml: 0.1ml/h---100ml/h         10ml: 0.1ml/h---200ml/h


20ml: 0.1ml/h---400ml/h        30ml: 0.1ml/h---600ml/h


50(60)ml: 0.1ml/h---1500ml/h



Drug names  



More than 20 drug names, such as  Epinephrine, Penicillin,Lidocaine, Vancomycin, Pitocin, Atropin, Insulin,  Heparin, Dopamine,and so on.



Injection increment 



0.1ml/h  



KVO rate



Adjustable, 0.1ml/h-5.0ml/h, choose “OFF”to cancel



Selectable modes



Rate mode,Body weight mode, Time mode



Rate mode



0.1~1500ml/h(maximum value depends on the syringe size)


Body weight mode

Body weight: 0.1~300kg    Volume limit: 0.1~999.9ml                             Drug limit: 0.1~999.9mg     Dose:0.1~9999.9mg


Unit: mg/kg/h, ug/kg/min (Subject to unit, dosage, liquid, weight and syringe)



Time mode



Time: 1-2000min   Volume limit: 0.1-999.9ml    



Preset range



0.1~9999.9ml



Accumulated volume 



0.1~9999.9ml 



Alarm function



NEAR, OVER, OCCL., low battery,  syringe disengaged, no AC power supply, error 1/2/3, preset volume alarm, serious low battery



Occlusion value



0.04Mpa – 0.16Mpa



Battery



Rechargeable lithium polymer battery 7.4V, 3000mA, working for 4 hours after being fully charged at 25ml/h.  



Preset time



0-99hour, 59 minutes



Panel instructions



1, Infusion rate  2,yringe pump  3, Battery capacity   4, Battery charging indication  5, Accumulated injection volume   6,AC power indicator 7,BED NO.  8, Alarm information, etc



Gross weight 



Less than 2.8kg



Overall maximum size



300*139*100mm (Length*Width*Height)



EMC



Meet the requirements of IEC60601-1-2(2007 version)



Classification 



Class II, type BF 



Electrical safety



Meet the requirements of EN60601-1:1990+A1:1993+A2:1995



Storage condition



Air pressure (50~106)kPa,  relative humidity≦95% Environment temperature: -20℃~+55℃.



Operation condition 



Air pressure (86~106) kPa,  relative humidity≦80% Environment temperature: 5℃~+40℃



Max power consumption 



25VA  



Power supply



AC100~240V   50/60HZ 



Vet syringe pump 



Previous:Painless H . Pylori Diagnostic Reagent C14 Urea Breath Test Kit of H . Pylori Detection

Next:Organic Sacha Inchi protein powder

Company profile

Epower Electronics & Science Co.,ltd

Learn more

Recommended products

Contact Now