H . Pylori Diagnostic Reagent C13 Urea Breath Test Kit with Gold Standard

Product description


Product Description




Delivery Time:Within 7 days after receipt of payment
Certification:CE /GMP / ISO 13485:2003/ISO 9001

H . Pylori Diagnostic Reagent C13 Urea Breath Test Kit with Gold Standard


Product Description:


H. Pylori Rapid Test kit:  13C Urea Breath Test for the clinical diagnosis of Helicobacter pylori (H.


Pylori) infection. As 13C is a kind of stable isotope, 13C Breath Test is applicable for all ages and types of


subjects, including pregnant women and young children.


Do you know​ H. Pylori?


Specification:




1.13C-Urea capsule: 75mg/grain/package

2. Breath bag: 2 PCS/package


3. C13 Urea Breath Test Kit: 20pcs/box 5boxes/carton


Main technical index


1. Repeatability: Average value ≤±0.3 (Condition: To measure a group of a standard gas sample that


include 3%CO2, DOB (‰) =2 for 10 times.


2. Precision: Standard error ≤0.3 (Condition: To measure a group of a standard gas sample that include


3%CO2, DOB (‰) =2 for 10 times.)


3. Sample volume need: ≥120mL/bag


4. The concertration range of CO2 sample: 1.5~6.0%;


5. Preheat time: about 30minutes, preheat time might shorten or extend automatically due to the influence


of environment temperature.


6. Sample measuring time: The time to measure a patient sample (including a bag of base sample and a


bag of sample gas) is about under 3minutes, the different CO2 concertration in sample will lead to


measuring time’s difference.



The advantages of C13 Urea Breath Test Kit












AccurateSensitivity 95%, specificity 95%-100%
ComfortableNon-invasive, no endoscopic tube insertion, well tolerated by patients
ConvenientNear-patient testing, analysis made on site, minimal inconvenience for patients
SimpleEasy operation, no special handling required
Swift The entire test is finished in 45 minutes, test result available on site

Procedure of Urea [C13] Breath Test:


1.Test on an empty stomach or 2 hours after the meal. Remove the cap of baseline breath bag, blow into


the bag smoothly, cover it after collecting full breath.


2.Take one 13C-urea capsule with 80-100 ml drinking water


3.Sit quietly for 30 minutes.


4.Remove the cap of sample breath bag, blow into the bag smoothly, cover it after collecting full breath.


5. Give baseline bag and sample bag to doctor.



Previous:Organic Coconut oil