Photovoltaic Insulation Monitor
Product description
Model No.: | 190010 | Description: | Insulation Monitor |
Applicable to 150V~850VD.C.DC floating system(IT system),real-time ground resistance measurement Measure DC voltage value(on power-on measurement);Continuously measure insulation resistance from 1KΩ to 10MΩ Use RS485 communication DC voltage range:150VDC~850VDC Supply voltage:9~18VDC or 18~36VDC Internal ground impedance:<1MΩ Insulation resistance detection range:1kΩ~10MΩ Communication method:RS485 Communication protocol: MODBUS Installation: DIN-Rail mounting Discharge of circuits:<30A Size(mm):110*45*75 | |||
Model No.: | 190011 | Description: | Insulation Monitoring Relay |
Suitable for high voltage 100V~1000VD.C.or low voltage 5V~50VD.C.Dc floating system(IT system) Insulation level setting 1KΩ~99KΩ Duration setting 0.05S~2.5S With two sets of fault relays(normally open and normally closed) With alarm indicator DC voltage range:5VDC~50VDC or 100VDC~1000vdc Supply voltage:18~36VDC or 85~265VAC/120~38VDC Alarm resistance setting range(panel):1~99kΩ Reset mode: Remote short sub reset or Manual reset Internal ground impedance:200kΩ Relay output form: Normally open and normally closed Communication method:RS485 Relay output contact:3A,250VAC/30VDC Installation: DIN-Rail mounting Size(mm):110*45*75 | |||
Model No.: | 190012 | Description: | Insulation Monitor |
Measure DC voltage value 0V~1000V Continuously measure insulation resistance of 0Ω to 20MΩ Use RS485 communication The alarm resistance threshold can be set. When the fault occurs, the relay will act and the indicator light will be on Digital display Optional with high voltage switch to ground DC voltage range:80VDC~1000VDC Supply voltage:18~36VDC Alarm resistance setting range(panel):10~90kΩ Alarm resistance setting range(communication):1k~20MΩ Insulation resistance detection range:1kΩ~20MΩ Reset mode: Remote short sub reset or Manual reset or Communication reset Communication protocol: MODBUS Communication method:RS485 Internal ground impedance:1024kΩ Size(mm):110*45*75 | |||
Model No.: | 190013 | Description: | Photovoltaic Insulation Monitor |
Real-time online measurement of ground current value Digital tube display RS485 OUTPUT With internal high-voltage grounding switch Alarm current setting range(panel):10~900mA Alarm current setting range(communication)1~65535mA Leakage current detection range:1~2000mA Reset mode: Remote short sub reset or Manual reset or Communication reset Communication method:RS485 Communication protocol: MODBUS Negative grounding impedance:2.5Ω Relay output form: Normally open Size(mm):110*45*75 | |||
Packaging Details: | Cardboard packaging inside, carton packaging outside ,anti-static | ||
Shipping: | By Express: DHL,UPS,TNT ; By Air Cargo; By Sea | ||
Payment: | PayPal, Western Union, T/T |