Photovoltaic Insulation Monitor

Product description


Product Description




Model No.:

190010

Description:

Insulation Monitor

Applicable to 150V850VD.C.DC floating system(IT system),real-time ground resistance measurement

Measure DC voltage value(on power-on measurement);Continuously measure insulation resistance from 1KΩ to 10MΩ

Use RS485 communication

DC voltage range:150VDC850VDC

Supply voltage:918VDC or 1836VDC

Internal ground impedance:1MΩ

Insulation resistance detection range:1kΩ~10MΩ

Communication method:RS485

Communication protocol: MODBUS

Installation: DIN-Rail mounting

Discharge of circuits:30A

Size(mm):110*45*75

Model No.:

190011

Description:

Insulation Monitoring Relay

Suitable for high voltage 100V1000VD.C.or low voltage 5V50VD.C.Dc floating system(IT system)

Insulation level setting 1KΩ~99KΩ

Duration setting 0.05S2.5S

With two sets of fault relays(normally open and normally closed)

With alarm indicator

DC voltage range:5VDC50VDC or 100VDC1000vdc

Supply voltage:1836VDC or 85265VAC/12038VDC

Alarm resistance setting range(panel):199kΩ

Reset mode: Remote short sub reset or Manual reset

Internal ground impedance:200kΩ

Relay output form: Normally open and normally closed

Communication method:RS485

Relay output contact:3A,250VAC/30VDC

Installation: DIN-Rail mounting

Size(mm):110*45*75

Model No.:

190012

Description:

Insulation Monitor

Measure DC voltage value 0V1000V

Continuously measure insulation resistance of 0Ω to 20MΩ

Use RS485 communication

The alarm resistance threshold can be set. When the fault occurs, the relay will act and the indicator light will be on

Digital display

Optional with high voltage switch to ground

DC voltage range:80VDC1000VDC

Supply voltage:1836VDC

Alarm resistance setting range(panel):1090kΩ

Alarm resistance setting range(communication):1k20MΩ

Insulation resistance detection range:1kΩ~20MΩ

Reset mode: Remote short sub reset or Manual reset or Communication reset

Communication protocol: MODBUS

Communication method:RS485

Internal ground impedance:1024kΩ

Size(mm):110*45*75

Model No.:

190013

Description:

Photovoltaic Insulation Monitor

Real-time online measurement of ground current value

Digital tube display

RS485 OUTPUT

With internal high-voltage grounding switch

Alarm current setting range(panel):10900mA

Alarm current setting range(communication)165535mA

Leakage current detection range:12000mA

Reset mode: Remote short sub reset or Manual reset or Communication reset

Communication method:RS485

Communication protocol: MODBUS

Negative grounding impedance:2.5Ω

Relay output form: Normally open

Size(mm):110*45*75

Packaging Details:

Cardboard packaging inside, carton packaging outside ,anti-static

Shipping:

By Express: DHL,UPS,TNT ; By Air Cargo; By Sea

Payment:

PayPal, Western Union, T/T



Previous:Fuse DC500V 10-50A

Next:Charging Pile Insulation Monitor(double-plug)

Company profile

Achates (Shanghai) International Trade Co.,Ltd.

Learn more

Recommended products

Contact Now