240VDC Battery Voltage High Frequency Online UPS Single Phase 10KVA

Product description


Product Description




Delivery Time:2 weeks
Certification:ISO 9001,CE

240VDC Battery Voltage High Frequency Online UPS Single Phase 10KVA
 
 
Quick Detail:
 

240VDC battery voltageCrest factor:3:1Input:(120±5)VAC~ (275±5)VACOutput:220VacRate Capacity:6K-240VDC battery voltagePower factor:0.8

 
 
Specifications:
 























Model

VT6K

VT6KS

VT10K

VT10KS

Rating

6KVA/4800W

10KVA/8000W

Input

Input system

Single phase & earth ground

Voltage range

(120±5)VAC~ (275±5)VAC

Power factor

≥0.99

Voltage range of bypass

(60±5)VAC~ (300±5)VAC (default: 60VAC~300VAC 
Could be adjusted by software)

Output

Output system

Single phase & earth ground

Rated voltage

220VAC  ①

Power factor

0.8

Voltage precision

±1%

Output frequency

Normal mode

1.The output frequency synchronizes with the input frequency 
when the input frequency is in the range of  46 Hz~ 54 Hz
2.The output frequency is 50Hz when the input
 frequency is not in the range of 46 Hz~ 54 Hz
3.Can be set as 60Hz

Battery mode

Inverter overload capacity
 (Utility power, 25℃)

105%±5%<Load≤125%±5% 60s transfer to bypass
125%±5%< Load <150%±5% 30s transfer to bypass
Load > 150%±5%, 300ms transfer to bypass

Transfer time

0ms (Normal mode←→ Battery mode)

<4ms (Normal mode←→Bypass mode)

Crest factor

3:1

Battery

Batteries voltage

192VDC

Battery quantity

16    ②

Battery Type

Sealed maintenance-free lead –acid battery 
of battery voltage 12V/7AH

Backup Time (25℃)

Full load≥5min (Standard)

Charge current

Standard  1A

Long  6.5A

① Note1: Output voltage can be set: 200V/208V/220V/230V/240V.
② Note2: 240VDC battery voltage can be choose

 
 
Zero power switch delay: When the utility power fails, UPS will automatically switch from AC mode to battery mode with no delay, which ensures stable power supply of operating system.
Active Load Management: This technology allows the UPS to be set up at a fixed 50Hz or 60Hz output, while it also can intelligently monitor power usage and automatically sheds and reconnects loads in order to prevent generator overload.
Sufficient Expansion Slots: The pre-allocated smart slots enable flexibility in choice of USB cards,AS400 cards, CMC monitoring cards, SNMP cards, RS485 cards and EMD environment monitoring cards.
The load power factor is 0.8: it adapts the features of most current electric equipment and elevates the load-bearing capacity of the machines.
Generator Supportable:The wide range of input voltage and frequency can effectively separate the harmful electric wave produces by the generators and provide safe and reliable power supply.

 

Previous:6KVA / 3KVA 2.4KW DC Online Uninterruptible Power Supply Low Frequency UPS

Next:6KVA High Frequency Online UPS 30KG Valve-Control Lead Acid Maintenance-Free Battery