330kV 720MVA High Voltage Power Transformers Oil Immersed For Power Plant

Product description


Product Description




Delivery Time:60-90 days
Certification:KEMA,SGS,ISO


330kV 720MVA High Voltage Power Transformers Oil Immersed For Power Plant



Quick Detail:



1.Low loss, low noise



2.Low partial discharge



3.High quality, efficiency



4.Safe use



5.Power transformer



Description:



Our company provide 330kV and below oil-immersed power transformer ,with capacity of 360 MVA and below. The 330KV transformer is based upon world-wide advanced technology and also incorporates the experiences of internationally leading transformer companies as well as our own long-term experiences.Our transformer conform entirely with latest national standard GB1094.1~2-1996, GB1094.3-2003, GB1094.5-2003 and international standard IEC-76. Outstanding features as follows:



1. Low loss, and significantly energy-saving. The average no-load loss is 35% lower than prescribed by National Standard GB/T 6451-2008.



2. The core laminations are made up from high-quality cold-rolled grain-oriented silicon steel sheets with chamfered joints and without punched holes, and are stacked without the upper yoke sheets in place, so that they are effectively improved no-load upper together with lower frame.



3. Zigzag directed flow of oil are provided within the windings, so that all parts of the windings can be cooled more evenly.



4. The regulating winding is a separate winding which apart from the high voltage main winding.



5. The windings of one phase are assembled into an integral phase block before placing into the core.



6. The winding manufacture, winding assembly core and winding assembly work are all proceed in totally closed clean department.



7. Core frames in the form of a flat plate are used for clamping the core, and are joined together by side beams.



8. Transformer tanks are fabricated with steel plates wide enough so that there are no weld joints on each surface.



9. Diaphragm membrane is provided within the conservator, preventing direct contact of oil with air, protecting the oil from aging.



10. Reliably sealed, and fine machined for sealed surface. Used double gasket grooves in their jointing surface and kept tight with high quality gasket material.



11. High quality paint is applied as surface finish of the tank and exposed steel parts, after shot-blasting and pretreatment, thus ensuring a durable life and glossy surface.



12. Quality assurance rules are also observed for all insulating parts, from raw material to final assembly.



13. Main components



Because of good relationship and long-term co-corporation with all well-known sub-suppliers, we can meet the requirements of customers with whatever types of components they wish to have.



Technical Parameter Specifications:




















Rated Voltage




330KV




Rated Capacity




720000KVA




Cooling Type




ONAN/ONAF/OFAF




Winding Type




Double winding / Three winding / Toroidal




Phase




Three Phase / Single Phase




Type




Core Type / Shell Type 




Winding Material




Copper




Frequency




50HZ / 60HZ



















Type:




S(F)(P)-720000




Voltage ratio:




345±2X2.5%



363±2X2.5%




Low voltage:




13.8



15.75



20




Connection symbol:




YNd11




Load Loss:




1120kW




No-load Loss:




245kW




Short Circuit Impedance




14~15




Applications:



Applied in residential buildings, business center, shopping center, small factories and so on.



A . Transformers application:



B . Production process:



Previous:Three Phase Electric Power Transformers With Two Separate Copper Winding