CW-5000AG Industrial Water Chiller for Single 80W/100W CO2 Laser Tube Cooling, 0.4HP, AC 1P 220V, 50Hz

Product description


Product Description





CW-5000AG Industrial Water Chiller for Single 80W/100W CO2 Laser Tube Cooling, 0.4HP, AC 1P 220V, 50Hz

It is designed for cooling the one CO2 glass laser tube under 150W of the 
laser engraving and cutting machine. (Its emitting rate is higher than 60 %.) 
Cooling capacity is 800W.
Have design patent Certificate, CE and RoHS Certificate.
This Water Chiller has been sold largely to Europe, South America, Asia and other markets.
Economic cooling equipment, easy to install and operate, compact and easily movable.

Features:
• It is suitable for cooling the laser tube under 150W, and the temperature can be adjusted precisely.
• You can choose different models according to local voltage and frequency.
• It can extend the using life of laser tube and ensure the engraving effect better.
• With completed water flow and over high temperature alarm functions
• It can control the water temperature, precision is ±0.3℃, which provide stable working conditions for laser devices.
• Multiple alarm function: compressor time-delay protection, compressor overcurrent protection, water flow alarm and over high / low temperature alarm;
• This series of water chillers adopt intelligent controller, which need not adjust the control parameters under normal 
circumstances, it will automatically adjust control parameters according to room temperature changes, to meet the cooling requirement.
• CW-5000 water chiller has unique low flow alarm protection function, which ensures the cooling water cycle working safely.
• Specific disconnection alarm securing protection.
• Enclosed water tanks, water used for a long time.
• Equipped with alarm output port, can quickly protect sensitive components.
• High cost performance, low failure rate.
• Multiple power specifications; CE approval; RoHS approval.

Details:
CW-5000AG Industrial Water Chiller for Single 80W/100W CO2 Laser Tube Cooling, 0.4HP, AC 1P 220V, 50HzCW-5000AG Industrial Water Chiller for Single 80W/100W CO2 Laser Tube Cooling, 0.4HP, AC 1P 220V, 50Hz 

 

Temperature controller panel:

CW-5000AG Industrial Water Chiller for Single 80W/100W CO2 Laser Tube Cooling, 0.4HP, AC 1P 220V, 50Hz
T
he cooling water circulation loop alarm causes and the work of the state table

 

 
Normal Flow
 Indicator
Flow Alarm
 Indicator
Buzzer
Output Ports
Hi, H2
Output Ports
H1, H3
Circulating pump works properlyONOFFNOT RINGDISCONNECTIONBREAKOVER
Blocked cooling water circulation loopOFFONRINGBREAKOVERDISCONNECTION
Alarm of water shortageOFFONRINGBREAKOVERDISCONNECTION
Faulted circulating pumpOFFONRINGBREAKOVERDISCONNECTION
Power interruption///BREAKOVERDISCONNECTION


Note: 
The flow alarm is connected to the normally open relay and normally closed relay contacts, requiring operating current less than 5A, working voltage less than 300V.

 Process:

CW-5000AG Industrial Water Chiller for Single 80W/100W CO2 Laser Tube Cooling, 0.4HP, AC 1P 220V, 50HzCW-5000AG Industrial Water Chiller for Single 80W/100W CO2 Laser Tube Cooling, 0.4HP, AC 1P 220V, 50Hz

Quality Report:

CW-5000AG Industrial Water Chiller for Single 80W/100W CO2 Laser Tube Cooling, 0.4HP, AC 1P 220V, 50HzCW-5000AG Industrial Water Chiller for Single 80W/100W CO2 Laser Tube Cooling, 0.4HP, AC 1P 220V, 50HzCW-5000AG Industrial Water Chiller for Single 80W/100W CO2 Laser Tube Cooling, 0.4HP, AC 1P 220V, 50Hz




Previous:3000mm x 2000mm Semi-Auto Acrylic Vacuum-Forming-Machine with Blow Press Suck Functions

Next:Luxury Manual Acrylic Letter Making Bending Machine Tool, A+U Type

Company profile

Beijing Chinasigns Information Co., Ltd.

Learn more

Recommended products

Contact Now