Quick Detail:
1)Two control modes: Air mode and baby mode controlled by micro-computer;
2)Humidity concentration display function (for NeoCare C);
Humidity concentration servo control (for NeoCare C1);
Humidity concentration servo control function and oxygen concentration display function(NeoCare C2);
Humidity concentration and oxygen concentration servo control function (for NeoCare C3);
3)Set temperature, air temperature, baby temperature, humidity concentration are displayed separately;
4) >37º C temperature set function;
5)Failure alarm indication;
6)Embedded integrated sensor box;
7)integrated water reservoir in the shape of drawer (for NeoCare C1)
8)Double wall Acrylic glass hood, automatic air circulation device;
9)Inclination of bassinet is adjustable;
10)RS-232 connector
Specification:
1)Power supply: AC220V-230V, 50Hz
2)Input power: 850VA(NeoCare C)
1000VA (NeoCare C1, C2, C3)
3)Mode of control: Air mode and baby mode controlled by micro-computer
4)Control range of air temperature: 25º C-37º C(override mode 37-39º C)
5)Control range of baby temperature: 34-37º C(override mode 37-38º C)
6)Accuracy of skin temperature sensor: ≤ 0.3º C
7)Variability of temperature: ≤ 0.5º C
8)Uniformity of temperature: ≤ 0.8º C(mattress is on the horizontal position)
9)Inclination of the bassinet: ± 12°
10)Noise inside hood: ≤ 60dB(A)
11)Failure alarm: Over temperature alarm, deviation alarm, sensor failure alarm, fan motor alarm, power failure alarm, sensor box position alarm and system alarm. (NeoCare C1 has low water alarm and tank position error alarm)
12)Indication range of humidity: 0%RH~99%RH
13)Control range of humidity: 20%RH~90%RH (for NeoCare C1)
14)Accuracy of humidity: ± 10%RH
15)Indication range of oxygen concentration: 0%~99% (for NeoCare C2)
16)Control range of oxygen concentration: 20%~60% (for NeoCare C3)
17)Accuracy of oxygen concentration: ± 3% (for NeoCare C2, NeoCare C3)
Requirements of environment:
Environment temperature: 20º C~30º C
(Set temperature should be higher 3º C than the environment temperature)
Wind speed of environment: ≤ 0.3m/s
Package:
Each unit is packed as two cartons
Size (Main body): 108.5mm x 64mm x 91.5mm
(Cabinet): 112.5mm x 66.5mm x 73mm
Gross Weight (Main body): 63Kg (for NeoCare C)
66Kg (for NeoCare C1)
66Kg (for NeoCare C2)
68Kg (for NeoCare C3)
(Cabinet): 68Kg (for NeoCare C, C1)
80Kg (for NeoCare C2, NeoCare C3)
Standard configuration:
NeoCare C: Main body (including the Acrylic glad hood, temperature controller, bassinet), skin temperature sensor, I. V. Pole, mattress, guard rail, mobile cabinet;
NeoCare C1: Based on NeoCare C, with Humidity servo control;
NeoCare C2: Main body (including the Acrylic glad hood, temperature controller, bassinet), skin temperature sensor, I. V. Pole, mattress, guard rail, mobile cabinet;
NeoCare C3: Based on NeoCare C2, with Oxygen servo control.
Optional configuration:
A. Fixed Neonate bilirubin phototherapy equipment model: BLT-90 (with blue flourencence lamps)
B. Fixed Neonate bilirubin phototherapy equipment model: BLT-90L (with LED blue lights)
C. Vertical Height Adjustment Stand (VHA Stand) Weighing System
The world trend of double inclined plane organic glass
Many countries adopt double inclined plane organic glass, which gives a visual sense of relaxed ease, a full range of observed objects without deformation and reflection, conveniently for medical staff monitor care.
Full open front door
Large front door, all the flip open, easy to operate for medical staff and easy to get in and out for infant.
Suitable temperature for infant
Temperature system adopts microcomputer control, high precise, small temperature fluctuation
Inclination of large bassinet is adjusted steplessly.
Infant bassinet tilt baby bed can be used for about 8 degrees of tilt, bed area is 10% larger than the average incubator.
Two-way pulling out of the bassinet
Bassinet can b e pulled out smoothly from the front door or right side door, to facilitate neonatal medical care.
X-ray cassette under the bassinet
China\'s first infant incubator with X-ray radiography, radiography cassette underneath beds, non-metal transparent window allow X-ray pass, no leaving the infant incubator for X-ray photograph.
Large display window for multi-parameters
Setting valu