Xanthene-9-carboxylic acid Pharmaceutical Intermediates CAS NO 82-07-5 98%

Product description


Product Description




Delivery Time:This is advantaged product, we have it in stock.
Certification:ISO9001

Xanthene-9-carboxylic acid  Pharmaceutical Intermediates  CAS NO 82-07-5 98%​


Quick Detail:



















Name



Xanthene-9-carboxylic acid



Appearance



White or off-white crystalline powder



Assay:



≥98.0



 Shelf life



two years



Loss on drying,%



≤1



Solubility(Methyl Ethyl Ketone)



Clear solution



MP/℃


221-225 °C(lit.)

Ignition residue,%



≤1



Description:


> Formula:C14H10O3


> Weight: 226.23


> Appearance:White or off-white crystalline powder


> MP:221-225 °C(lit.)


> Storage:room temperature


> Danger Description:R36/37/38


> Safety  Description:S26 S36


> Danger Symbol:Xi


> Shelf life:two years


Specifications



























Assay



≥98.0



MP,℃



221-225 °C(lit.)



Loss on drying,%



≤1



Xanthene,%



≤0.5



Ignition residue,%



≤1



Xanthone,%



≤0.5



Ultraviolet absorbance/260nm(55% aq.)




Ultraviolet absorbance/280nm(55% aq.)




Dicyandiamide,%




Melamine,%




Iron,ppm




shelf life



two years



Synonyms:


9H-XANTHENE-9-CARBOXYLIC ACID;9-XANTHENECARBOXYLIC ACID;XANTHENE-9-CARBOXYLIC ACID;XANTHANOIC ACID;xanthoic acid;Xanthene-9-carboxylicacid,98%;Xanthine-9-carboxylic acid;Xanthanoic Acid (100 mg);xanthoic acid; Methyl xanthene-9-carboxylate; 9-Xanthene carboxylic acid; Xomthene-9-carboxylic methylester acid; 9H-xanthene-9-carboxylic acid; 9H-xanthene-9-carboxylate


Related categories:Drug bulk;Aromatic Carboxylic Acids, Amides, Anilides, Anhydrides & Salts;Heterocyclic Building Blocks;O-Containing;Others;Building Blocks;Chemical Synthesis;Heterocyclic Building Blocks


Related Products:92-83-1


Determination of melting point


   Instrument:


   Micro melting point apparatus WRS-2A, Melting point tubes


  Determination of step:


Open switch, stable 20min.


First set the starting temperature than the melting point of the low 10 ℃, heating rate 2 ℃ / min.


The sample was grind as fine as possible and load in a clean, dry melting point pipe ,until the sample was compressed into about 1cm high .When the actual temperature reaches the set temperature and stabilized . Inserted into the capillary with the sample, the simultaneous determination of three.


The determination of Loss on drying


  Weigh a sample of approximately 2g (weighing accuracy 0.0001g),Record the weight of m,The sample was placed in a Petri dish constant weight (weight recorded as m0), the tile, the thickness of not more than 5mm, into the oven (As next dish cover removed) drying at 105-110 ℃ 3 hours.When removing, make sure the dish cover,be placed in a desiccator to cool, then weighed and the weight (including surface dish) m1.


Loss on drying in accordance with the following formula:


Where:


         m-- sample, g


       m0-- dish, g


          m1-- After drying the quality of the sample and the dish, g


The determination of residue on ignition


   First the Griddle was burning 30 minutes at 600 ± 50 ℃, cooled and then weighed on a silica gel drier.Taking 1g sample was placed in a crucible and weighed, with 2ml sulfuric acid (5.5ml98% sulfuric acid diluted to 100ml) wetting the sample which was slowly heated until the sample completely low zoom.Cooling,using 2ml sulfuric acid (5.5ml98% sulfuric acid diluted to 100ml) to wet the sample, which was slowly heated until no white smoke, and then placed at 600 ±50℃ calcined to obtain the residue, to ensure that the entire process does not  produce white smoke.Cooling Griddle silica gel dryer and then weighed to calculate the mass of the residue.



Previous:4,5,6,7-Tetrahydrothieno[3,2-c]pyridine Hydrochloride Pharmaceutical Intermediates CAS NO 28783-4

Next:Good quality bamboo ice cream stick for sale

Company profile

China Chemical Product Online Market.

Learn more

Recommended products

Contact Now